• basic workflow to test functionality:
    • sample data: SSC402 HighContentAuthor SignalsScreeningv27.zip
    • recording: Call with Cruz Espinoza, Judith (Guest)-20230630_105045-Meeting Recording.mp4
    • step by step summary of the recording:
      1. Data import
            File upload (next)
            SciStream Data Import template
                1st folder - all (C:\Users\Admin\Desktop\SSC402 HighContentAuthor SignalsScreeningv27\Lesson - Basic Authorship Workflow\1_Data Files\B43ScreeningPlates)
            (next)
            Plate -> plate ID
            row -> Row Letter
            Column -> Column
            Features --> Raw Data
            Annotation --> Assay Date, Plate Barcode
            - see the screenshot
            (apply)

      2. Configuration

        • load the SciStream Data Import template - see the screenshot

      3. Grid Plate Editor
            floppy > 2nd folder > json
            Concentration
            (apply)

      4. Editable data grid
            floppy > 3rd folder > Compounds IDs - b34_single_day.txt
            New columns - see screenshot
            Plate ID - Plate ID
            Well Type - Well Type
                see screenshot

      5. Extensible Normalization
            Well Type
            Raw Data
                - screenshot
            (next)

            Negative controls -> Background
            Positive controls -> Uninhibited
                - screenshot
            (apply)


      6. New Curve Fitting
            - screenshot

      7. file > save  - creates backup

      8. + Create new workflow
            From existing document
            test installation

      9. Workflows
            here you can find the published installation


  • No labels